Boot field output block n301 (tdq3654) the pin voltage is normal, check N201 (tda8362) on the field scan pins 41, 42 end, the voltage is almost normal, just 42 feet than normal 2.8V low voltage 0.2V, check the resistance r392 (3.6m) open, replacement, repairDjiservice manual download site