Mitsubishi M52340 microcontroller heart KAICNG-colour TV when the green light is still showing no raster state, but turn off the main power in the middle of the screen to show the vertical light momen

Time£º2014-05-19 07:46:20  Source£ºNetwork  Author£ºUnknown  Clicks£º1384
  

Boot with an oscilloscope view of the investigation, line pipe V432 c highly unstable anti- peak frequency flyback waveform , the DC voltage 1lOV stable.Cqdservice manual download site

    This failure is like an open circuit fault line deflection coil , the horizontal deflection circuit to check the deflection coil connector rows found only three wires ( typically four ) , which has received two field deflection coils, and only one connection line deflection coil. Then check the other wiring line deflection coil through - an independent plug plugged into the line output transformer T471 ¢â foot end , the line deflection coil loop ( different from the random drawing ) as shown in the drawings . The inspection found that the resistance value between the T471 2,10 feet large, detached 2,10 feet and then measuring its resistance is ∞. Normal approximation to 0Ω.Cqdservice manual download site

    According to the user to reflect : Before this failure had twice overhauled others , and replace the line output transformer T471; aircraft initial failure is repeated firing line pipe , replace the T471 is no longer firing line pipe , but now becomes a symptom .Cqdservice manual download site

    According to the preliminary examination and users reflect the situation analysis , first solve the problem of unreasonable T47l 2,10 feet . Analysis: boot on the firing line pipe line output transformer causes and unrelated , but after replacing the T471 repairer had no firing line pipe is T47l 2,10 foot barrier just a coincidence. Because when T471 2,10 foot barrier is the line deflection coil open loop ( which is a special connection machine BOC deflection circuit ) , thus making V432 load reduction , which is V432 c Current drastically reduced , this even when there have been adverse incentives and other factors , it will not be firing line pipe . It is this coincidence was the former mender into errors. Therefore, we can determine the original line output transformer is not damaged. Put it back into the circuit , re- correct maintenance.