Appeared before searching, abnormal sound fault could not be locked program. AFT and image after intermediate frequency coil is changed after everything is back to normal (intermediate frequency IC TA8611AN). But to turn it off after a few hours, boot, image sound distortion after 10 seconds, a LO hop luo and noise, preheat before 30 minutes audio returned to normal. After watching some longer, and found a strange phenomenon, in the remote control to turn it off and then turned on fault described above. If directly to shut off the power switch, switch on again, everything is all right. But if use the remote control to turn it off, then boot failure appeared above said. 4jKservice manual download site
4jKservice manual download site
4jKservice manual download site
This machine failure may be caused by the following two conditions: 1. The sound signal processing circuit, especially audio frequency coil and filter capacitor is defective. 2. May be a control system for power supply and reset circuit filter capacitance performance is bad.4jKservice manual download site
|