This machine easily zoom soft belt break. Telescopic soft belt fracture, internal shutter lens can not open, but the lens can back and forth telescopic, the telescopic soft fault zone.fw9service manual download site
1 replacement method and steps
(1) the first camera strap from the body down, so that the lens is fully retracted to the closed state, and then remove the battery.
(2) unscrew and remove the 3 screws at the bottom of a camera (of which 1 is black, the other two silver).
(3) 2 silver screw loose and take on both sides of the right camera camera straps (note that the 2 screws for long), and then remove the three nuts and bolts.
(4) unscrew and remove the camera left 1 silver fixing screw.
(5) open the camera back cover, unscrew and remove the camera power switch at the side and the left side of the viewfinder eyepiece 1 black screws.
(6) carefully separate the front cover and back cover, pay attention not too hard, so as not to break the cover body.
(7) after the front cover open, electrical parts of the interior are exposed. At this time should be to prevent the high voltage electric shock in the circuit. First, to the main capacitor discharge (the main capacitor is located in the top right is the battery chamber above the camera, as shown in Figure 1a). Tear tape can short the main capacitor discharge; discharge after a moment, then the second discharge, ensure that the power drain.
(8) the solder joint loosening and fastening screw on the motherboard and wire (note the electrostatic, the electric iron can heat the operation, the power plug using the pull off to avoid electrostatic breakdown Motherboard Components and CPU), and then carefully lift the motherboard slowly removed.
(9) on the motherboard near a connector above LCD data display side, remove (do not use electric iron) are careful with tweezers stuck to the front of the lens connector hard slowly loosen, then you can remove the soft belt connection point, as shown in Figure 1b.