This is a common fault Amoi phones. To clock circuit to work properly, which is essential for several conditions powered clock , the clock frequency , cpu and software . A6, a8 series phones Time Reset main problem lies in the power supply, when the phone when the battery is removed , the clock circuitry on the board of a battery-powered 3mah spare capacity , the capacity of the battery itself or a problem with the external circuit , the clock data exists ram fellow travelersykFservice manual download site
Loss of access to access to relevant information found spare battery bt400 external components for the filter capacitor c408, and then all the way through to the 0 ohm r420 power management IC u501 of j3 foot , the other way to the main screen chip select electronic switch v403 was measured . : required voltage 2.6v or so, current <= 4ma normal clock circuit , so that when repairs are usually the fault plane , first test bt400 whether the absence of voltage 2.6 ~ 3.0v , then remove bt400, check if poor ;. bt400 in fine , the power supply can be adjusted to 3v output , and placed in series with a multimeter 50 microamps file backup plus 3v voltage on the PCB - battery place, observe the meter pointer is greater than 4 microamps ; If more than four micro- Ann and put the pointer without instability phenomenon , then remove the v403, v503, check whether leakage ( available exclusion ) , leakage and replace through the above steps , the problem can be solved.
|