Symptom: Z9Aservice manual download site
1. The drain can not self-locking, there have been a small amount of water discharged at work, to begin the cycle time for several hours before being washed.
2 dehydration have a great sound, and there is a great shock. (Previously)
Analysis:
Also has a variety of features, power, and other normal, so the first rule out electrical problems. Richard mechanical failure: check the drain valve normally open cabinet. After opening rotation will find there are a lot of impurities, clear it, fold to Drainage Department, found two one-dollar coin, removal, installation, operation, failure above all excluded.
Summary:
Such problems often occur, get to find out what the reason, I hope you have a little experience when need it.
It seems a small problem can also cause a major disaster! ! !
|