fire - 17% of the power output.9GKservice manual download site
9GKservice manual download site
4 , fire selector by the fire selector switch S5 common synchronous motor with integrated timer device composed mainly used to control the input power transformer energization , which regulate the work of the magnetron / stop the proportion of time, thereby regulating the microwave output power . There are 6-speed microwave firepower : High Fire - 100% power output ; high fire - 85% power output ; fire - 66% power output ; low fire - 40% power output ; thaw - 37% power output ; low fire - 17% power output.9GKservice manual download site
9GKservice manual download site
5 , the thermostat also called self-resetting thermal breaker (S6), in series with the input of low-voltage circuits mounted on top of the magnetron housing . It is mainly used to control the operating temperature of the magnetron , normal use will not operate . If for some reason causing the magnetron operating temperature is too high , S6 automatic disconnection , disconnect the power ; when the temperature returns to normal , S6 automatically closed , power.9GKservice manual download site
9GKservice manual download site
6, the fan motor fan motor M2 is a single -phase shaded pole micro motors, speed 200 rev / min , mounted on the back side next to the magnetron .