Easy Microwave main components detection methods

Time£º2014-05-07 09:54:17  Source£ºNetwork  Author£ºUnknown  Clicks£º1310
  
8XZservice manual download site
2 ) in a direction normal resistance is infinite , in the other direction is greater than 100kΩ8XZservice manual download site

     5 , bidirectional diode ( also known as protection diode ) method :8XZservice manual download site
     1 ) The instrument is set to the highest resistance range ;8XZservice manual download site
     2 ) Disconnect the wires , the protection diodes separated from the circuit ;8XZservice manual download site
     3 ) normal phenomenon should be tested at both ends of the protection diodes from two directions , the resistance value is infinite. If it is damaged , will exhibit continuity in one or two directions .8XZservice manual download site